Sorry, nothing was found. Please change your selection and try again.
Showing 1 - 40 of 59 results
Filters
Sort by:
Best Match
Best Match
Price: Low to high
Price: High to low

Eltako 22110011 Electromechanical Switching Relay 1 NO + 1 NC 16A R12-110-12V
Electromechanical switching relay with manual operationModular device for mounting on DIN-EN 61075 TH35 rail1 module width = 18mm, 55mm deepContacts: 1 normally closed, 1 normally openDuty cycle: 100%Control power requirement: 1.9WContact spacing: 3mm, test voltage: 2000V (contact to contact), 4000V (control terminal to contact)

Eltako Impulse Relay ESR61M-8..230V UC
Multifunction momentary-contact relay for flush mounting5 selectable functions: momentary-contact switch or relayContacts: 1+1 normally closedNo standby loss, no constant power supply requiredDimensions: 45mm long, 45mm wide, 32mm deepUniversal control voltage: 8-230V AC/DCState-of-the-art hybrid technology for wear-free electronic controlSuitable for incandescent lamps up to 2000W and LED lamps up to 230V

Eltako Field Disconnect Switch for Series FR12.1-230V
Field switch for row, 1 normally closed contact, 16A/250V ACRated voltage: 230V, rated current: 10A, rated frequency: 50HzMax. incandescent lamp load: 2300W, max. fluorescent lamp load: 500VAStand-by power consumption only 0.8 wattsSelf-learning field switch with state-of-the-art hybrid technologyInterrupts power supply after shutdown of downstream consumersThreshold adjustment is automatic via patented processModular device for mounting on DIN-EN 50 022 mounting rail, 1 module width = 18mm, 55mm deep
£55.03

Eltako FT55-wg wireless switch pure white glossy with rocker and double rocker
Wireless Push Button FT55-wg 80x80mm outer dimensions, frame inner dimensions 55x55mm, 15mm heightBatteryand wiring-free wireless technologyEncryptable wireless telegramsInstallation: screw-on or adhesiveGenerates energy for wireless telegrams itself when pressedSmart Home SensorDimensions: 80x80mm outer, frame inner dimensions 55x55mm, 15mm height

Eltako Switching Relay R12-020-230V
Electromechanical switching relay with 2 normally closed contactsManual operation and position indicator included100% duty cycleControl power consumption of 1.9WContact gap of 3mmTest voltage contact/contact: 2000V, test voltage control terminals/contact: 4000VSuitable for mounting on DIN-EN 60715 TH35 mounting railUniversal control voltage from 12-230V AC/DC

source: OnBuy
Eltako Impulse Dimmer Switch EUD12NP-8..230VUC
Universal dimmer switch for lamps up to 400WAutomatic lamp detectionMinimum or maximum brightness adjustableAdjustable dimming speedWith child room and snooze functionModular device for mounting on DIN railUniversal control voltage 8..230V UC
£44.82

Eltako NR12-001-3x230V - Network Monitoring Relay NR12-001-3x230V
Power monitoring relay with phase sequence monitoringStandby loss only 0.8 wattsModular device for mounting on DIN rail (1TE)Monitoring of 230V AC voltage between 1 to 3 phases and the neutral conductorMonitoring of phase sequence (clockwise rotation) in the rotary switch positions 2Ph and 3PhIf L1 fails, the relay drops out immediately without drop-out delayLED indicator for correct applied voltageAdjustable drop-out delay from 0.1 to 8 secondsPick-up delay of 0.5 secondsMaximum device fuse 16A

Eltako Impulse Relay ES12Z-200-8..230VUC
Eltako Impulse Relay ES12Z-200-UCElectronic switch for DIN rail mountingWidth: 1 module, Installation depth: 58 mm2 normally closed contacts, Rated switching current: 16 AControl voltage 1: 8-230 V AC/DC, Frequency: 50 HzControl voltage 2: 8-230 V, Frequency: 50 HzSelectable functions: Central ON and OFF, Central ON only, Central OFF only, No central control
£46.96

Eltako R12-110-24VDC - Switching relay for row bus R12-110-24VDC
Electromechanical switching relay with manual operation and switching position indicatorDuty cycle: 100%, control power consumption: 1.9WContact gap: 3mm, test voltage contact/contact: 2000V, test voltage control terminals/contact: 4000VModular device for DIN-EN 60715 TH35 mounting rail1 modular unit: 18mm wide, 55mm deepVarious contacts available: 1 normally open, 2 normally open, 1 normally open and 1 normally closed, 2 normally closed (only 230V)Suitable for mounting in control cabinets

ELTAKO FR61.1-230V Power-Off Relay
Eltako Field Switching Relay Blue 10A 230V 611005301 normally closed contact, not potential-free 10A/250V ACStandby loss only 0.8 wattsFor flush mounting, dimensions: 45mm long, 45mm wide, 26mm deepSupply and switching voltage 230VInterrupts power supply after shutdown of downstream consumersAutomatic learning of inrush current and switching off for low consumersLow ripple of DC voltage 230V DC

Eltako Impulse Relay for Flush/Surface Mount S81-002-230V
Electromechanical latching switch with manual operationSwitch position indicator availableDimensions: 50mm long, 42mm wide, 32mm deepDuty cycle: 100%Control power requirement: 5-5.5WContact gap: 2mm2 changeover contacts with a rating of 10A/250V AC

Eltako 22200030 Electromechanical Switching Relay 2 Normally Closed Contacts 16A R12-200-230V
Electromechanical switching relay with manual operation and switching position indicator100% duty cycleControl power requirement of 1.9WContact gap of 3mmTest voltage contact/contact of 2000VTest voltage control terminals/contact of 4000VSuitable for flush and surface mounting

Eltako 21200002 Electronic impulse relay 2 NO ES12-200-8..230V UC
Eltako ES12-200-UC impulse relay for DIN rail mountingControl voltage 8-230 V/DC or 230 V with max. 5 mA glow lamp currentSwitching capacity max. 20 A/230 V across both contacts2 potential-free normally closed contacts 16A/250V ACElectronic impulse relay

Eltako LS - Light Sensor LS
Light sensor LS with photoresistorModifies voltage depending on brightnessEvaluation in sensor relay LRW12DDurable plastic housing, protection class IP54Mounting with screw and nutCompatible with Apple HomeKit, Google Assistant, Amazon Alexa, IFTTT not supportedDimensions: 38x28x95mm

Eltako R 12 100 24V DC
Modular device for DIN-EN 60715 TH35 mounting railManual operation and switch position indication1 modular width, 18mm wide, 55mm deepDuty cycle: 100%, control power consumption: 1.9WContacts: 1 normally closed, 2 normally closed, 1 normally closed and 1 normally open, 2 normally open (only 230V)Contact gap: 3mm, test voltage: 2000V contact to contact, 4000V control terminal to contact

Eltako KR09-24V UC - Coupling Relay KR09-24V UC
Potential-free contact closer 6A/250V ACSuitable for 230V LED lamps up to 50W, incandescent lamps up to 500WNo standby lossModular device for mounting on DIN-EN 60715 TH35 railState-of-the-art hybrid technology combines electronic control with high performance of special relaysControl voltages 24V DC, control indicator with LED

Eltako S12-220-230V 4-pole impulse relay
Eltako momentary contact switch S12-220-230V (21220030)4-pole 16A/250V ACDIN rail mounting devices for installation on DIN-EN 60715 TH35 mounting railsManual operation and switching position indicator2 modular units = 36mm wide, 55mm deepContacts: 2 normally open + 2

Eltako 22100054 Electromechanical Switching Relay 1 Normally Closed Contact 16A R12-100-12VDC
Modular device for DIN-EN 60715 TH35 DIN rail mountingManual operation and switching position indicator1 modular width unit = 18mm wide, 55mm deepDuty cycle 100%, control power consumption 1.9WContacts: 1 normally closed contact, contact gap 3mmTest voltage contact/contact 2000V, control terminals/contact 4000VCompatible with electronic switching relays ER12DX-UC, ER12-200-UC, and ER12-110-UCUniversal control voltage UC: 12-230V AC 50-60 Hz, 12-230V DC

Eltako Multifunction Timer Relay MFZ12NP-230V+8..230V
1 changeover contact not potential-free 16A/250V AC230V LED lamps up to 200W, incandescent lamps 2300W*Standby loss only 0.5 wattsContact switching at zero crossing to protect contacts and lampsState-of-the-art hybrid technology combines the advantages of wear-free electronic control with the high switching capacity of special relaysTimes adjustable between 0.1 seconds and 40 hoursFunctions: RV, AV, TI, TP, IA, EW, AW, ARV, ON, OFFLED indicates contact position during timing

Eltako 22200011 Electromechanical Switching Relay 2 Normally Closed Contacts 16A R12-200-12V
Electromechanical switching relay for DIN rail mountingManual operation and switching position indicatorDuty cycle 100%Control power consumption 1.9WContact gap 3mmTest voltage contact/contact 2000VTest voltage control terminals/contact 4000V

Eltako 22200020 Electromechanical Switching Relay 2 Normally Closed Contacts 16A R12-200-24V
Modular device for mounting on DIN-EN 60715 TH35 mounting railManual operation and switching position indicator1 modular pitch = 18mm wide, 55mm deepDuty cycle 100%, control power consumption 1.9WContacts: 1 normally open, 2 normally open, 1 normally open and 1 normally closed, 2 normally closed (latching relay, 230V only)Contact gap 3mm, test voltage contact/contact 2000V, test voltage control terminals/contact 4000VAlso compatible with ER12DX-UC, ER12-200-UC, and ER12-110-UC electronic switching relays

Eltako 22200930 Installation Contactor 2 Normally Closed Contacts 25A XR12-200-230V
2-pole 25A/250V ACModular devices for mounting on DIN-EN 60715 TH35 railsManual operation and switching position indicator1 module width = 18mm wide, 55mm deepDuty cycle 100%Control power consumption 1.9WContacts 2 normally closedContact gap 3mmTest voltage contact/contact 2000VTest voltage control terminals/contact 4000V

Eltako Radio Switch Staircase Light NLS FTN61NP-230V
1 normally closed contact, not potential-free, 10A/250V ACSuitable for 230V LED lamps up to 400W and incandescent lamps up to 2000WReturn delay with switch-off warning and switchable push-button continuous lightEncrypted radio, bidirectional radio, and repeater function switchableStand-by loss only 0.8 wattsFor flush mounting, dimensions: 45mm long, 45mm wide, 33mm deepContact switching at zero crossing to protect contacts and consumers

Eltako XR12-310-230V Installation Contactor
Installation Contactor XR12-310-230V4-pole, 25A/250V ACModular devices for mounting on DIN-EN 50 022 railManual operation and switching position indicatorControl power consumption only 4W2 modular units = 36mm wide, 55mm deepContacts: 3 Normally Closed, 4 Normally Closed, 3 Normally Closed and 1 Normally Open

Eltako FK Window Contact
Window contact with reed relay, 1 normally closed contactSwitching capacity 5W or VA, switching voltage max. 175V ACMagnet opens the normally closed contact when approaching less than 25mmConnection terminals for easy installationIsolation relay ETR61NP switches power supply of a range hood when window is openMounting the FK window contact: pry out inserts, connect reed relay, cut out housing opening, adhere or screw housingRadio frequency=868 MHz, rolling code system=no, range=30 m, number of commands=2, radio remote control=no

ELTAKO FSM61-UC Wireless Transmitter Module Flush-Mounted EnOcean BUILDING TECHNOLOGY > Sensors > GT
Wireless 2-channel transmission module for flush mountingWith internal antenna, no standby lossCan send wireless telegrams like a wireless pushbuttonControl commands from 8 to 253V AC or 10 to 230V DCMaximum parallel capacitance of control lines at 230V: 5nFNo continuous power supply requiredRotary switch to enable/disable encryption

Eltako XR12-220-230V - Installation Contactor XR12-220-230V
Eltako Installation Contactor XR12-220-230V2 modular units = 36mm wide, 55mm deepContinuous duty 100%Control power requirement 4WContacts: 2 normally closed, 2 normally openTest voltage contact/contact 2000V, control terminals/contact 4000VProtection rating (IP): IP20

source: Amazon
Eltako KR09-12V/UC Coupling Relay KR09
Coupling relay for mounting on DIN-EN 60715 TH35 DIN railWidth of 9mm modular spacing, 55mm depthNo standby lossHybrid technology combines electronic control with special relayControl indicator with LEDControl power consumption only 0.2W
£26.57

Eltako Switching Relay for Row EB R12-200-24V DC
Modular device for DIN-EN 60715 TH35 mounting railManual operation and switching position indicatorDuty cycle 100%, control power consumption 1.9WContact gap 3mmTest voltage contact/contact 2000V, control terminals/contact 4000V2-pole 16A/250V ACDimensions: 1 modular width, 18mm wide, 55mm deep

Eltako R12-310-230V Electromechanical Switching Relay
4-pole switching relay for mounting on DIN-EN 60715 TH35 mounting railManual operation and switching position indicator included100% duty cycleControl power consumption is 4WContact gap of 3mmTest voltage contact/contact: 2000VTest voltage control terminals/contact: 4000VEltako installation relay R12-310-230V (22310030)

Eltako Impulse Relay ES12Z-110-8..230VUC
For DIN rail mountingControl voltage 8 230 V/DCAdditional control inputs for centralized on and centralized off with 8 230 V/DC (galvanically isolated)Neon lamp current max. 50 mA from 100 V control voltage (only possible for certain functions)Switching capacity max. 20 A/230 V across both contactsTwo rotary switches for functions and priorities

Eltako 21110055 Electromechanical Impulse Relay 1 NO + 1 NC 16A S12-110-24VDC
Electromechanical impulse switch with manual operationSwitch position indicator included100% duty cycleControl power consumption of 5-6WContact gap of 3mmDistance between control terminals and contact greater than 6mmSuitable for building installation and control technology

Eltako XS12-220-230V - Impulse Relay XS12-220-230V
Eltako Power Pulse Switch XS12-220-230V (21220930)For DIN EN 50022 mounting railsRated switching capacity 25 A/250 V AC2 Normally Closed, 2 Normally OpenElectromechanical Power Pulse SwitchManual operation and switching position indicatorDuty cycle: pulse control only

Eltako ES12-100-8..230V UC - Impulse Relay ES12-100-8..230V UC
Eltako ES12DX-UC impulse relay, 1 potential-free normally open contact, 16A/250V ACControl via multi-voltage input (8-230V) or 230V with max. 5mA glow lamp currentModular device for installation on DIN-EN 60715 TH35 mounting railSuitable for manual operationNo standby loss, low power consumption during control pulseDimensions: Width 18 mm, Depth 58 mm
Refine Search
Filters
Clear All
Category
✓Price
✓Brand
1Seller
0















